  ,. analog w devices 3y2 digit ac line powered dpm i ad2009 features ac line powered bright, seven segment gas discharge display bcd data outputs standard hold and -(rigger control signals full scale ranges of :t1.999v or :t199.9mv display blanking control industry standard panel cutout applications general purpose dpm applications requiring ac power and a high visibility display data logging and digital feedback control systems general description the ad2009 is a low cost 3'h digit, ac line powered dpm de- signed for general purpose dpm applications. the ad2009 measures bipolar input voltages over full scale ranges of either :t1.999v or :t199 .9mv, with an accuracy of :to.l % reading :tl digit and displays the readings on large, bright 0.55" (i4mm) beckman gas discharge displays. large, bright display for display only applications, the beckman display offers ex- cellent appearance and visibility. the ad2009 display is easily read up to 50 feet (ism) away and over all ambient lighting conditions. the non-glare lens allows a choice of either red or amber display colors, and is easily silk-screened with company logo or measurement units. external control of decimal points and display blanking is provided. simple data interfacing since the ad2009 is designed around ttl logic circuits, paral- lel bcd data, ttlldtl compatible, is a standard feature, allowing easy interfacing to a variety of data peripherals, such as digital comparators and line printers. under internal con- trol, the ad2009 converts at a nominal rate of six conversions per second. using the hold and trigger controls, up to 100 conversions per second can be externally triggered. industry standard case design in response to industry's urgent need for dpm standardization, analog devices has adopted the most popular ac powered dpm panel cutout size for the ad2009 and all future ac line pow- ered dpm's. since this 3.924" x 1.682" (99.67 x 42.72mm) panel cutout is used by so many ac powered panel meters, the potential dpm customers can be assured that second-sources i nformation furnished by analog devices is believed to be accurate and reliable. however, no responsibility is assumed by analog devices for its use; nor for any infrir.gements of patents or other rights of third parties which may result from its use. no license is granted by implica- tion or otherwise under any patent or patent rights of analog devices. will be available and future new products will be usable without mechanical changes to their instruments or systems. designed and built for reliability design and manufacturing techniques are chosen to insure reli- ability in the ad2009. conservative design techniques and thorough component evaluation are only the beginning. manu- facturing processes are monitored by continuous quality assur- ance inspections to insure proper workmanship and testing. like every other analog devices' dpm, each ad2009 is fully tested for electrical specifications, calibrated, and given one full week of failure free burn-in before shipment. theory of operation the ad2009 uses a dual slope conversion technique with an absolute value voltage to current converter input. the entire conversion cycle takes less than 10 milliseconds, allowing a complete conversion to be done during the negative half cycle of the ac line, and the resulting reading is displayed during the positive half cycle of the ac line. this scheme not only insures a flicker free display, but also allows externally trig- gered conversions at rates up to loa/second for data inter- facing applications. in order to insure a bright display even during operation at low line voltages and to help insure the reliability of the beckman displays, a separate power supply is provided to continually illuminate two "keep-alives" in the beckman display. route 1 industrial park; p.o. box 280; norwood, mass. 02062 tel: 617/329-4700 twx: 710/394.6577 west coast mid-west texas 213/595-1783 312/894-3300 214/231-5094 obsolete
specifications (typical @+25c and nominal line voltage) display output . beckman seven segment gas discharge display, 0.55" high (14mm) for three data digits, 100% overrange and negative polarity indication. overload indicated by blanking the three data digits and displaying the "1" overrange. the polarity remains valid. . decimal points selectable at input. . display blanking analog input . configuration: bipolar, single ended . full scale range: :t1.999v or :t199 .9m v (see s option) . automatic polarity . input impedance: 100md.dc . bias current, both ranges: 3na @ 2v fs, 20na@ 200m v fs . overvoltage protection, both ranges: 200vdc sustained accuracy . :to.1 % :t1 digiti . resolution: 1mv or 100pv (s option) . temperature range2: 0 to +50c operating -25c to +85c storage . temperature coefficient: gain (both ranges) - :t60ppm/oc zero offset (2v input) - :t30pv / c (200mv input) - :t10pv/oc . warm-up time to rated accuracy: 15 minutes . settling time to rated accuracy: 0.3 see normal mode rejection . 18 db @ 60hz common mode rejection (lkd. source imbalance @ 50- 60hz, with standard shielded transformer) . 2v input - 100db . 200mv input - 80db common mode voltage . :t300vdc (600v ac pip) (floated on power supply transformer when bcd outputs and control signals are not used) conversion time . 10msec conversion rate . internal trigger: 6 conversions per second . external trigger: 0-100 conversions per second digital control signals . dtl/ttl compatible in logic "0" 2.0v control inputs3 . display blank (1 ttl load). logic "0" or grounding blanks the entire display, not including the decimal points. logic "1" or open circuit for normal operation. display blanking has no effect on output data and the display reading is valid immediately upon removal of a blanking signal. . hold (1 ttl load). logic "0" or grounding disables either the external or internal trigger and the last con- version is held and displayed. . external trigger (1 ttl load). positive pulse (5 oopsee max width) will initiate conversion. out <0.4v >2.4v . decimal points (not ttl compatible). grounding will illuminate the desired decimal point. external drive cir- cuitry must be capable of withstanding loov when the decimal points are turned off. data outputs3 . 3bcd digits (drives 6ttl loads). positive true, unlatched . overrange (drives 6ttl loads). unlatched, logic "0" indicates overrange (;;;'1000). . overload (drives 6ttl loads). unlatched, logic "0" indicates overload (;;;'2000). . polarity (drives 6ttl loads). latched, logic "1" in- dicates positive polarity. . status (drives 10ttl loads). all digital outputs are valid when status is at logic "0". logic "1" indicates conver- sion is in progress. . internal trigger output (not ttl compatible). when connected to external trigger input will cause the ad2009 to convert at 6 conversions per second. this output can only be used for triggering the ad2009. power input . ac line, 50-60hz, 4.2 watts at 60hz; 4.7 watts at 5 ohz (at nominal line voltages). calibration adjustments . gain . zero . recommended recalibration interval - 6 months size . 4.18"w x 1.93"h x 4.15"l (106 x 49 x 112mm) . 4.7i'l (121mm) to rear of card edge connector . panel cutout required: 1.682 x 3.924" (42.72 x 99 .67mm) weight . 15 ounces (425 grams) options4 - ordering guide . ac power inputs (50-60hz) ad2009 - 11 7v ac ad2009 ie - 220v ac ad2009/f - 100v ac ad2009/h - 240vac :t10% . ad2009 - 1.999vdc full scale ad2009/s - 199.9mvdc full scale . lens 7 - red with adi logo lens 8 - red without adi logo lens 13 - amber with adi logo lens 14 - amber without adi logo connector . 30 pin, 0.156" spacing card edge connector, amphenol 225 -215 24-601 (117) or equivalent c) optional: order ac2611 @ $4.50 j;-rlc~ .o.<" c' ~lq1'>., pricing '~'?j' .. ", m'p $140( ' . ) a.',.)..j~ 'l?j.~. . unit quantity . consult factory for oem quantity pricing 1 guaranteed @ +2soc. 2 guaranteed. 3 not to be used when the ad2009 is floating on common mode voltages. 4 only one input range and ac power input may be specified. 5 lens 7 is supplied if no lens option is specified, specifications subject to change without notice, ') --- obsolete
i applying the ad2009 interf acing the ad2009 input connections the ad2009 has a single ended input with common analog and digital grounds. when digital control lines and bcd data out- puts are not used, the entire dpm can be floated on the power supply transformer at up to 300vdc common mode voltages. if these signals are used, care should be taken to insure against ground loops within the system causing erratic and/or errone- ous readings. decimal poi;ts grounding the proper pin will illuminate the desired decimal point. if external logic drives are used to control the decimal points, drive circuitry must be able to withstand 100v when the decimal points are turned off. display blanking the entire display (excluding decimal points) may be blanked by applying logic "0" or grounding the proper control input (pin 13). blanking the display has no effect on the output data or the conversion process. the data remains valid during blanking and the dpm reading is correct immediately upon re- moval of the blanking signal. interfacing digital data outputs the digital data outputs of the ad2009 are unlatched, positive true, parallel bcd, at dtl/ttl logic levels. as shown in the timing diagram (figure 1), all data outputs are valid when the st a tus line is low. the status line is high during conver- sion when erroneous data will be present on the outputs. triggering conversions the ad2009 may be triggered internally at six conversions per - second, or externally at rates of up to 100 conversions per second. for internal triggering, the internal trigger output (pin 1) should be connected to the trigger input (pin b). for external triggering, a positive trigger pulse ?soo}..ts width) should be applied to the trigger input (pin b). whether in- note 1 ~nx;ee~n~ll ~~igger ~ i i conversion cycle 1 1 i i i i ~~~~~~ate i i reference integrate i note 2 i i i i status --1 data v":lld ~ ~ ~~'l~~'ty ~~~~ notes' ,. moni",uon p"l,e width 100m. m...m"m 500", 2. ap"",,'m"te!y 10? he1",e coove"oo" '~9"" figure 1. ad2009 timing diagram ternal or external triggering is used, the last reading can be held and displayed by grounding or applying logic "0" to the hold input. at high conversion rates, the display may flicker unless synchronized to the ac line input, but data outputs will remain valid. calibra non procedure "warning: for the safety of personnel and interconnected equipment, all calibration should be done using a plastic trim- ming tool only." a precision voltage reference is needed for calibration of the ad2009. the location of calibration potentiometers is shown in figure 2. before calibrating the ad2009, allow the unit to warmup to normal operating temperature. always adjust the zero offset first then the gain. zero adjustment: short the signal input (pin 2) to the signal ground (pin 10) and adjust the zero adjustment pot until the meter reads 000. gain adjustment: apply an input of +1.900v (+190.0mv on ad2009/s) and adjust the gain pot until the meter reads 1900 exactly. mounting block 4.15 (1051 marking to appear on top surface 026 (6.61 + lens ~ l~ ~i b.b.b l1( . zero adjust gain adjust key between pins 5 & 6 ,- 15 t ~ analog ~ devices made" usa 1.67 14241 snap in mounting block i . i ~ 3.92 19'i.gi 1 figure 2. ad2009 mechanical outline (dimensions shown in inches and (mm)) 1 zh 09-05 :j'ri/\ ool 0 :1 zh 09-05 :j'ri/\ ovl 0 h zh 09-05 :j'ri/\ oll 0 3 4.77 zh 09-05 :j'ri/\ l u 0 (121) l- alddos 113mod noi.ldo goozov i. 4.18110.621 obsolete
compress mounting block to snap into slot " ;~ panel thickness 0.0625 to 0.125 (1.61 to (3.21 mounting instructions: 1. slide dpm through panel cutout from front of panel. 2. snap mounting block into slot on dpm sides. 3. tighten mounting block tension screws snugly to secure dpm to panel (do not overtighten!) 4. snap lens onto front of dpm. figure 3. ad2009 mounting instructions (dimensions shown in inches and (mm)) ! pin 1 and pin b must be connected for operation with internal trigger. key figure 4. ad2009 signal and pin designations -- pin ref pin function 1 internal trigger out! 2 signal input 3 status (print) 4 polarity 5 bcd8 6 bcd2 7 bcd 80 8 bcd 20 9 bcd 800 10 signal ground 11 bcd 400 12 bcd 200 13 display blank 14 overrange 15 ac line hi pin ref pin function a no connection b external trigger in1 c overload 0 hold e bcd 1 f bcd4 h bcd 10 j bcd 40 k bcd 100 l dp3/xx.x m dp2/x.xx n digital ground p dp1/.xxx r shield (earth ground) s ac line lo obsolete


▲Up To Search▲   

 
Price & Availability of AD2009-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X